bannière
Des produits
Maison /

DEC

/Yokogawa S2SC70D-FA412010 Duplexed Safety Control Unit
Yokogawa S2SC70D-FA412010 Duplexed Safety Control Unit
Yokogawa S2SC70D-FA412010 Duplexed Safety Control Unit
Yokogawa S2SC70D-FA412010 Duplexed Safety Control Unit

Yokogawa S2SC70D-FA412010 Duplexed Safety Control Unit

This General Specifications (GS) provides the hardware specifications of the safety control unit, which are intelligent parts of the safety control station (SCS). This product supports both N-IO and FIO.


  • Marque :

    Yokogawa
  • Numéro d'article :

    S2SC70D-FA412010
  • Lester :

    13kg
  • Dimension :

    38.2x22.2x5.5cm
  • Pays d'origine :

    Japen
  • Code SH :

    8537101190
  • La description :

    Duplexed Safety Control Unit

Contact and Submit your Inquiry

Sales Manager - Frida

Phone/Whatsapp:
+86 15359408275

Email:
sales5@mooreplc.com

Address:
Xiamen,Fujian,China


General Information

Product ID:
S2SC70D-FA412010
Long Description:
Duplexed Safety Control Unit, ProSafe-RS, for N-IO/FIO, Rack Mountable Type, Wide Range Temperature (-20 to 70°C) with Fan Unit and ISA G3, S2CP471 Processor (Dual-redundant), Always 1, Always 1, 24 V DC Power Supply, With Explosion Protection, With ISA Standard G3, Always 0.


Additional Information

Medium Description:
Duplexed Safety Control Unit, ProSafe-RS, Wide Temp, 24 VDC, Explosion Protected, ATEX

Product Type:
Safety Control Unit (Duplexed, Rack Mountable)
HS Code:8537101190



Technical

F:

wide range temperature (-20 to 70 °C) type (with Fan unit and ISA Standard G3)

A:

S2CP471, Dual-redundant Vnet/IP, dual-redundant power supply (*2)
4:

SCP461, Dual-redundant Vnet/IP, dual-redundant power supply (*3)

1:

100 - 120 V AC power supply 
0:

With no explosion protection

1:
With ISA Standard G3
0:
Always 0
Power Supply Voltage:24 V DC
Power Consumption:7.0 A (24 V DC model)



FAQ




Can two S2CP471 modules and replace them ourselves during a scheduled shutdown?
No. The specification explicitly states that user replacement from SCP461 to S2CP471 is prohibited.
What is the difference between suffix "1" and option "/ATDOC"?
Suffix "1" = physical explosion protection hardware. /ATDOC = ATEX/UKEX documentation package. Both are required for full ATEX compliance.
Do I need the fan version (-F) if my control room is air-conditioned?
No. The standard type (-S, -20 to 40°C) is sufficient for air-conditioned rooms. The -F type is required only when ambient temperature exceeds 40°C.


Delivery & Payment




Transportation Methods
(1)DHL,UPS,TNT,CHIRLINE,FEDEX
(2)We arrange the shipment for you
(3)Using your own shipping forwarder
Delivery time
Only 3-5 days can arrive after payment
Package
Original packing with cartons.
Payment Term
T/T
Shipment Mode
EXW/DAP


Other Models You May Like

ADR541-P10 S1

ADV151-P00 S2

ADV561-P00 S2 

ADR541-P11 S1

ADV151-P00 S2  ATD5A-00

ADV561-P10 S1

ADR541-S00 S1

ADV151-P03 S2

ADV561-P11 S1

ADV141-P10 S1

ADV151-P50 S2

ADV569-P00 S1

ADV141-P12 S1

ADV159-P00

AFV10D S2

ADV141-P13 S1

ADV159-P01

AI-917-00

ADV141-S12 S1

ADV161-P00 S2 

AIP502

ADV141-S13 S1

ADV169-P00 S1

AIP502 S1

ADV142-P10 S1 

ADV551-P00 S2

AIP512

ADV142-P13 S1

ADV551-P00 S2  

AIP532 S1

ADV142-S02 S1

ADV551-P03 S2

AIP562 S1

ADV142-S03 S1

ADV551-P50 S2

AIP827-2 S1

ADV151-P00

ADV551-P53 S2

AIP827-2 S1


laisser un message
Si vous êtes intéressé par nos produits et souhaitez en savoir plus, veuillez laisser un message ici, nous vous répondrons dès que possible.
  • API
  • DEC
  • STI
  • SIGS

Nouveaux produits

Produits connexes