A2FU2‐1100‐S1

The A2FU2‐1100‐S1 is a Yokogawa Primary Power Distribution Unit for FCU use with the A2BE1D base plate. Confirm the complete identifier, 100–120 V AC supply, READY contact wiring and cabinet installation before ordering.

CATALOGA2FU2‐1100‐S1
IDENTITYExact label
SYSTEM100–120 V AC · READY contact · M4 terminals
STATUSOfficial data available
BRANDYokogawa
PRODUCT TYPEPrimary Power Distribution Unit (for FCU)
CONDITION / WARRANTYOriginal New · One-Year Warranty
VERIFICATIONPhotos and video after inquiry
REQUEST A QUOTE
  • Marque :

    Yokogawa
  • Numéro d'article :

    A2FU2‐1100‐S1
  • La description :

    Primary Power Distribution Unit (for FCU)
MODEL SEARCHFind a specific part numberOpen the best-matched Moore Automation product page directly.
PRODUCT INFORMATION● OFFICIAL DATASHEET
PRODUCT REFERENCE VERIFICATION

A2FU2‐1100‐S1

CONFIGURATION VERIFICATION

EXACT MODEL · 100–120 V AC · READY CONTACT · M4 TERMINALS

PRODUCT ROLE
A2FU2‐1100‐S1 is Yokogawa’s Primary Power Distribution Unit for an FCU built with the A2BE1D base plate. It provides the power-input interface and READY contact output; confirm the full identifier, supply voltage, cabinet installation and terminal wiring before use.
INSTALLATION CHECK
Confirm the A2FU2‐1100‐S1 mounting on the A2BE1D base plate, 100–120 V AC supply, M4 power terminals, READY NC/C contact wiring and keyed metallic cabinet before replacement.
👩‍💼
WANT THE BEST PRICE?
Frida
Sales Leader 🏆
EMAILsales5@mooreplc.comWHATSAPP+86 153 5940 8275
ORDER NUMBER BREAKDOWN

A2FU2‐1100‐S1 model code analysis

A2FU2
Base modelPrimary Power Distribution Unit (for FCU)
-1100‐S1
Suffix code analysis-1: 100–120 V AC · 1: fixed code · 0: Basic type · 0: fixed code · S1: appended marking; verify on the product nameplate
OFFICIAL YOKOGAWA REFERENCE

Technical Specifications

OPEN OFFICIAL DATASHEET
A2FU2‐1100‐S1

Verified A2FU2‐1100‐S1 data at a glance

Confirmed values from Yokogawa GS 33J60E60-01EN for the A2FU2 Primary Power Distribution Unit.

Complete referenceA2FU2‐1100‐S1
Identity evidenceA2FU2 model and -1100 suffix
System evidence100–120 V AC supply · M4 terminals · READY contact output
CompatibilityCheck complete suffix and system fit
Verified configuration

Yokogawa GS 33J60E60-01EN identifies A2FU2 as the Primary Power Distribution Unit for FCU use. The -1100 suffix specifies 100–120 V AC, fixed code 1, Basic type and fixed code 0.

GENERAL INFORMATION
BrandYokogawa
ModelA2FU2‐1100‐S1
Product categoryPrimary Power Distribution Unit (for FCU)
Compatible base plateA2BE1D
Power supply100–120 V AC
Frequency50/60 Hz
Power input terminalsM4 screw terminals
READY terminals2 terminals (NC and C)
READY contact actionOpens during FCU failure
READY contact rating30 V DC, maximum 0.3 A
Approx. weight0.2 kg
Installation requirementInstall in a keyed metallic cabinet
Verification statusOfficial A2FU2 specification available
Official Documentation
Official datasheet statusGS 33J60E60-01EN official specification available
Exact catalog matchA2FU2‐1100‐S1 model and -1100 suffix confirmed; appended S1 marking requires nameplate confirmation
Required confirmationProvide the complete A2FU2‐1100‐S1 label, A2BE1D base-plate identity, supply voltage, M4 terminal wiring, READY contact wiring and replacement quantity.
Ordering Check
Lifecycle and replacement statusNo direct-successor statement was located in the cited Yokogawa specification. Verify the A2BE1D base plate, 100–120 V AC input, terminal layout and cabinet requirements before substitution.
Quotation evidenceProvide the complete A2FU2‐1100‐S1 label, A2BE1D base-plate identity, supply voltage, M4 terminal wiring, READY contact wiring and replacement quantity.
Source: Yokogawa GS 33J60E60-01EN; no third-party product specifications are used.
FAQ

A2FU2‐1100‐S1 Compatibility, Installation and Ordering FAQ

What is A2FU2‐1100‐S1 and what does it do?

A2FU2‐1100‐S1 is Yokogawa’s Primary Power Distribution Unit for FCU use. It provides the power-input interface and READY fault-contact output; the complete identifier, A2BE1D base plate and supply must match before use.

Which system and interface are required for A2FU2‐1100‐S1?

A2FU2‐1100‐S1 is used with the A2BE1D FCU base plate. Confirm the 100–120 V AC input, M4 terminals, READY contact wiring and keyed cabinet rather than treating A2FU2‐1100‐S1 as a generic power part.

What configuration or performance data applies to A2FU2‐1100‐S1?

A2FU2‐1100‐S1 uses the -1 supply code for 100–120 V AC at 50/60 Hz. Yokogawa lists an approximate unit weight of 0.2 kg; the appended S1 marking still requires label confirmation.

Which electrical, network or protection options must be confirmed for A2FU2‐1100‐S1?

Confirm the READY output’s two NC/C terminals, 30 V DC maximum 0.3 A contact rating and M4 screw-terminal connection for A2FU2‐1100‐S1 installation.

What must be checked before installing or replacing A2FU2‐1100‐S1?

Match the complete A2FU2‐1100‐S1 identifier, A2BE1D base plate, supply voltage, M4 terminal layout, READY contact wiring and keyed cabinet before replacement.

How is A2FU2‐1100‐S1 different from a related model?

A2FU2‐1100‐S1 uses -1100 to denote 100–120 V AC, fixed code 1, Basic type and fixed code 0. A2FU1 is a separate HKU Interface Unit, so the two units are not interchangeable.

What identification and ordering evidence is needed for A2FU2‐1100‐S1?

Provide the complete A2FU2‐1100‐S1 model and suffix, photos of the S1 marking, A2BE1D base-plate identity, supply voltage, terminal wiring and quantity. Use official GS 33J60E60-01EN to confirm the -1100 code; do not infer the appended S1 marking.

CONTACT PRODUCT SPECIALIST

Check A2FU2‐1100‐S1 configuration with Frida

Provide the complete A2FU2‐1100‐S1 label, A2BE1D base-plate identity, supply voltage, M4 terminal wiring, READY contact wiring and replacement quantity. Share the installed-system photographs and destination for verification.

CHOOSE A DIRECT CONTACT METHOD
DATA SHEET

Manuals and Official References for
A2FU2‐1100‐S1

Official manufacturer-reference information for the Yokogawa A2FU2‐1100‐S1 Primary Power Distribution Unit (for FCU).

Official datasheet status

Yokogawa GS 33J60E60-01EN is the official A2FU2 specification. It identifies A2FU2 as the Primary Power Distribution Unit for FCU use and defines the -1100 power and type suffix codes.

OPEN OFFICIAL DATASHEET

Contact to Get Support

Send the complete model, quantity, and your technical or purchasing question.

Technical statements on this page are derived from Yokogawa GS 33J60E60-01EN.

PRIMARY POWER DISTRIBUTION UNIT · FCU

How A2FU2‐1100‐S1 Fits a Yokogawa FCU

Yokogawa is the brand; A2FU2‐1100‐S1 is a Primary Power Distribution Unit for FCU use; -1100 identifies the documented supply and type codes, while the appended S1 marking should be checked on the nameplate.

Yokogawa · BRAND
Primary Power Distribution Unit (for FCU)100–120 V AC · M4 TERMINALS
SYSTEM ROLE

A2FU2‐1100‐S1 · FCU POWER INPUT

A2FU2‐1100‐S1 provides the A2BE1D-based FCU with a primary power-input interface and READY fault-contact output.

TERMINAL / CABINET FIT

M4 · KEYED METALLIC CABINET

Confirm the 100–120 V AC input, M4 screw terminals, READY NC/C contact wiring, A2BE1D mounting and keyed metallic cabinet before commissioning.

CONFIGURATION DATA

READY CONTACT · 30 V DC MAX 0.3 A

Yokogawa specifies two READY terminals (NC and C); the contact opens during FCU failure and is rated 30 V DC, maximum 0.3 A.

System relationship: verify the complete A2FU2‐1100‐S1 label, A2BE1D base plate, 100–120 V AC supply, M4 terminal wiring, READY contact and S1 marking before installation or replacement.
VERIFICATION EVIDENCE

Evidence needed to verify A2FU2‐1100‐S1 correctly

Product Identity

Match A2FU2‐1100‐S1 to the complete Yokogawa product label, -1100 suffix and installed hardware record.

Installation Context

Document the A2BE1D FCU base plate, 100–120 V AC source, M4 power terminals, READY contact terminals, cabinet and wiring.

PRODUCT REFERENCEA2FU2‐1100‐S1Complete A2FU2‐1100‐S1 product reference
Configuration Evidence

Use the complete identifier, GS 33J60E60-01EN official specification, nameplate photographs and installed-system record to verify identity.

Replacement Check

Do not substitute another catalog number until the complete identifier, supply voltage, A2BE1D fit, terminal arrangement and READY contact requirements are verified.

ABOUT MOORE AUTOMATION

A trusted industrial automation sourcing partner

Moore Automation Limited supplies industrial automation spare parts to customers worldwide, with dedicated sourcing, part-number verification, pre-shipment confirmation and responsive sales support.

Global sourcing Pre-shipment verification One-year warranty
SERVICE

Industrial Automation Order Support

A clear workflow for sourcing, verification, shipment preparation, delivery and product assurance.

STAGESERVICE ACTIONWHAT WE CHECK OR PROVIDE
01PROCUREMENT
Product SourcingCurrent, hard-to-find and discontinued industrial automation parts.
02VERIFICATION
Part Number ReviewComplete model, suffix, nameplate, visible revision and application details.
03CONFIRMATION
Pre-Shipment CheckModel, label, condition and packaging confirmed with actual photos or video.
04FULFILLMENT
Global Delivery
Worldwide delivery with flexible shipping options. We support door-to-door pickup or delivery to your nominated freight forwarder in China.
DHLFedExUPSTNT
05ASSURANCE
One-Year WarrantyOne-year warranty from delivery for products supplied by Moore Automation.
Warranty Claim Information
What to provide: If a product-related issue occurs within the warranty period, contact our team and submit one clear, continuous video for review.
Complete product and nameplate
Power supply and wiring connections
Installation and operating conditions
Indicator lights, alarms or error messages
Clear description of the fault
Continuous video showing the issue
Review outcome: If the evidence confirms a covered product fault, Moore Automation will arrange the appropriate warranty solution.
SALES ASSISTANCE

Contact Sales Manager Frida

Include the complete part number, quantity and delivery destination.

EMAILsales5@mooreplc.com WHATSAPP+86 153 5940 8275
laisser un message
Si vous êtes intéressé par nos produits et souhaitez en savoir plus, veuillez laisser un message ici, nous vous répondrons dès que possible.
  • API
  • DEC
  • STI
  • SIGS
Produits connexes